WEAVE Open-Time Phase 2. Instructions for Applicants

Important links and documentation

WEAVE Automated Submission Platform (WASP):  http://wasp.ast.cam.ac.uk/

...

WEAVE Open Time programme: https://www.ing.iac.es/astronomy/observing/WEAVE-OT.html

Communication with the PI

The WEAVE Automated Submission Platform (WASP) automatically emails the principal investigators (PIs) with A detailed description of how the observations are processed and eventually released can be found in the WEAVE data model documentation:

  1. Login to WASP or the OR.
  2. Click on ("Tools" and select "Data Model").
  3. In section "Resources", click on the "Documentation" tab and download WEAVE-ICD-030: "Interface between SPA and SWG/QAG (info for WASP etc)".

Communication with the PI

The WEAVE Automated Submission Platform (WASP) automatically emails the principal investigators (PIs) with submission deadlines, validation acknowledgements and any other important information concerning the preparation of phase 2. These The first two emails contain the words [WEAVE-WASP] at the beginning of the subject line.  

Summary of actions

...

the following (the subject line is provided):

  1. An email containing the credentials to log onto WASP:
    Subject: [WEAVE] Account created for WEAVE observation preparation
  2. A following email contains information about the opening of the OB submission window:
    Subject: [WEAVE-WASP] 20XXXX WASP upload window now open

General assistance can be provided at the following email:

weave_open_time_support@ing.iac.es

Summary of actions

GREEN: Actions by the PI
PURPLE: Actions by the PI if familiarised with the package "IFU Workflow", or by ING on behalf of the PI, if assistance is requested by the PI to weave_open_time_support@ing.iac.es

...

The instructions below are mainly aimed at PIs who will request assistance to:

weave_open_time_support@ing.iac.es

LIFU mode: catalogue preparation

Target declination and right ascension

...

limits

WASP sets limits to allowed target RA and Dec. WASP The current target declination limit is -25º. Objects with a declination lower than that cannot be observed. 

WASP sets limits to allowed target RA and Dec, and it will not validate your OB is if your target coordinates lie outside the limits for that trimester. The total length (counted as science exposure time) of all the OBs submitted over the two trimesters can't exceed the science time allocated to your proposal in that semester (see time allocations).

...

20h (300º) → 16h (240º)

...

See below the allowed RAs for each trimester.

Trimester A1

2h (30º) → 20h (300º)

Expanded range:
2h-3h-4h-...-0h18h-1h-2h-...-16h
300º-315º-330º19h-20h
30º-45º-60º-...-270º-15º-30º-...-240º

> -25º
Trimester A1
OB submissionObserving periodAllowed RAsDec limit
~weeks before observing period starts1 Feb - 30 Apr

2h (30º) → 20h (300º)

Expanded RA range:
2h-3h-4h285º-300º

Trimester A2

9h (135º) → 2h (30º)

Expanded range:
9h-10h-11h-...-18h0h-19h1h-20h
30º-45º-60º2h
135º-150º-165º-...-0º-15º-30º

Trimester B1

15h (225º) → 9h (135º)

Expanded RA range:
15h-16h-17h-...-270º7h-285º8h-300º

> -25º

Download the catalogue template

Log on to WASP with the username and password provided in an email you must have received from WASP. Go to "My survey" and click on "Download template".

Image Removed

Alternative catalogue template

Alternatively, a simple template in CSV format can be used. Below it's a template with one target:

<filename: WS2023B2-001_target_list.csv>
TARGID,TARGNAME,GAIA_RA,GAIA_DEC,PROGTEMP,OBSTEMP,IFU_DITHER
SN2017fgc_host,SN2017fgc,20.0602,3.4028,41331,TCCBD,3

Filling out the catalogue template with targets

These are the columns in the catalogue template we request PIs to fill in:

TARGPROG (optional)
TARGID
TARGNAME
GAIA_ID (if available)
GAIA_RA
GAIA_DEC
GAIA_PMRA (if available)
GAIA_PMDEC (if available)
GAIA_PARAL (if available)
PROGTEMP
OBSTEMP
IFU_DITHER
IFU_PA_REQUEST (if necessary)

TARGPROG

TARGPROG is an optional column, to be filled out at the discretion of the catalogue creator.

TARGID and TARGNAME

This parameter is used to group IFU observations of the same target, in cases where stacks are required. This helps the Core Processing System (CPS) responsible for obtaining the data, to identify cases where the same astrophysical target is observed but the OBs executed were not related.

An example would be LIFU observations of the core of M33. If a user requires 3 OBs, each with different dither positions, then the CPS could not ordinarily stack these data, because they do not share the same Central CNAME (CNAME is the WEAVE object name from coordinates).

It is not always true that IFU observations with common TARGNAME will be stacked. Only common TARGNAMEs with sufficient overlap will be stacked by the CPS. However, if Contributed Data Products exist to create larger mosaics from these data, then they should use the common TARGNAME to group L1 products.

For IFU fields, this is the OB-specific descriptor of the field.  An example of TARGIDs of OBs with different pointings, could be a simple numerical identifier for each OB:

• OB1: TARGNAME = “M33bulge” TARGID = “M33bulge1”
• OB2: TARGNAME = “M33bulge” TARGID = “M33bulge2”
• OB3: TARGNAME = “M33bulge” TARGID = “M33bulge3”

But for overlapping OBs, TARGID could be more descriptive:

...

PROGTEMP

The PROGTEMP code is an integral part of describing how the instrument is configured. This parameter encodes the requested instrument configuration, OB length, exposure time, spectral binning, cloning requirements and probabilistic connection between these clones.

...

Instrument configuration

Check first what instrument modes are available in the ING announcement of opportunity

OB length

This PROGTEMP component specifies the overall OB length (inclusive of overheads). Please be aware that not all OB lengths are available. 

Arm exposures

It defines how the time within the OB that you wish to observe the target is divided up, by specifying the number of exposures and exposure time within the stipulated OB length.  The listed options of exposure time splits correspond to science open-shutter times (note that every exposure incur a 3-minute overhead).

...

Binning in the spectral direction

Only listed values are allowed, all other values are forbidden. As an aside, note that there is no facility to request spatial binning. Such a mode would compromise the spectral extraction performance and crosstalk characterisation within the L1 pipeline.

Duplicate this OB 'x' times

This component is entirely optional – validation checks will not fail if there is no 'x' value in the PROGTEMP. If an applicant wishes to duplicate the observations of this target, then duplication would result in the OB this target lives in being duplicated 'x' times, or in other words, one only OB will be generated, but it will be cloned 'x' times when ingested into the observing system.

...

9h
225º-240º-255º-...-105º-120º-135º

Trimester B2

20h (300º) → 16h (240º)

Expanded RA range:
20h-21h-22h-...-14h-15h-16h
300º-315º-330º-...-210º-225º-240º

Total requested time

The total length (counted as science exposure time) of all the submitted OBs can't exceed the science time allocation of your proposal (see the time allocations).

Preparation of the catalogue

The catalogue can be prepared in three alternative ways:

  1. Filling in the FITS catalogue template provided on WASP. Log on to WASP with your credentials. Go to "My survey" and click on "Download template".

Image Added


2. Converting the above FITS catalogue template into CSV and filling in.

3. Filling in a simplified CSV version of the catalogue template. Below it's an example of this simplified template and 4 catalogue rows that each describe an OB definition:

<filename: WS2023B2-001_target_list.csv>
TARGID,TARGNAME,GAIA_RA,GAIA_DEC,PROGTEMP,OBSTEMP,IFU_DITHER
IC768_1,IC768,76.7836980,18.1489034,61331.3,DAFEA,3
GHMon,GHMon_NW,32.591451,23.910124,60881,IADEE,4
SN2024gtp,SN2024gtp,102.644083,+68.252231,43331.3,DACEA,6
M101HIIregionC1,M101HIIregion,161.2533346,-11.7653604,51001.7+,AAAEA,0


Filling out the catalogue template with targets

Any of the three catalogue templates above (FITS, CSV, simplified CSV) can be filled in with targets. These are the requested columns (the rest are optional). If not specified, the data release version and epoch of the GAIA coordinates will be DR3 and 2016.0 respectively. 

TARGPROG (optional)
TARGID
TARGNAME
GAIA_ID (if available)
GAIA_DR (optional)
GAIA_RA
GAIA_DEC
GAIA_EPOCH (optional)
GAIA_PMRA (if available)
GAIA_PMDEC (if available)
GAIA_PARAL (if available)
PROGTEMP
OBSTEMP
IFU_DITHER
IFU_PA_REQUEST (if necessary)

TARGPROG

TARGPROG is an optional column, to be filled out at the discretion of the catalogue creator.

TARGID and TARGNAME

This parameter is used to group IFU observations of the same target, in cases where stacks are required. This helps the Core Processing System (CPS) responsible for obtaining the data, to identify cases where the same astrophysical target is observed but the OBs executed were not related (via for example the "chained" directive).

An example would be LIFU observations of the core of M33. If a user requires 3 OBs, each with different dither positions, then the CPS could not ordinarily stack these data, because they do not share the same Central CNAME (CNAME is the WEAVE object name from coordinates). In the input FITS catalogue, these observations are represented by 5,427 rows: 603 fibres, dithered 3 times for 3 OBs. Each of these rows must be tied together by a common TARGNAME, e.g. "M33 bulge". This indicates to the CPS that these observations should be evaluated for stacking.

Image Added
Above: Three LIFU dither positions centred on a putative target. This information must be encoded in the input FITS catalogue, but grouped by common TARGNAME.

It is not always true that IFU observations with common TARGNAME will be stacked. Only common TARGNAMEs with sufficient overlap will be stacked by the CPS. However, if Contributed Data Products exist to create larger mosaics from these data, then they should use the common TARGNAME to group L1 products.

Image Added
Above: Example LIFU coverage of an extended source. Each colour here represents an OB. Within each pointing there would be a series of dithers (as per previous Figure). Whilst these pointings might share the same TARGNAME ("M33"), the CPS would recognise these as a mosaic and not stack them into a single LIFU data cube.

The TARGID is the target identifier and it is mandatory that this column is filled in.

For IFU fields, this is the OB-specific descriptor of the field.  In the first example above, this could be a simple numerical identifier for each OB:

OB1: TARGNAME = “M33bulge” TARGID = “M33bulge1”
OB2: TARGNAME = “M33bulge” TARGID = “M33bulge2”
OB3: TARGNAME = “M33bulge” TARGID = “M33bulge3”

For the second example, TARGID could be more descriptive:

OB1: TARGNAME = “M33” TARGID = “M33 bulge”
OB2: TARGNAME = “M33” TARGID = “M33 disc NE”
OB3: TARGNAME = “M33” TARGID = “M33 disc NW”

PROGTEMP

The PROGTEMP code is an integral part of describing how the instrument is configured. This parameter encodes the requested instrument configuration, OB length, exposure time, spectral binning, cloning requirements and probabilistic connection between these clones. We refer registered WASP users to the PROGTEMP form: http://wasp.ast.cam.ac.uk/progtemp(there is also a copy at ING: https://a.ing.iac.es/weave/progtemp.php ).

Please use this exposure time calculator for your signal-to-noise calculations: https://a.ing.iac.es/signalWEAVE/. There is more information, including a downloadable version, at WEAVE Exposure Time Calculator .

OBSTEMP

Whilst PROGTEMP deals with “how” a target is observed, OBSTEMP deals with “when” a target is observed – namely setting the observational constraints required to optimally extract scientific information from the observation.

These constraints represent “worst-case” observing parameters – targets will be observed under these conditions or better. Note, however, that the worst case represents a scenario when all worst-case observational constraints meet simultaneously. PIs should note also that the probability of observing targets with highly restrictive OBSTEMP codes may be quite low.

We refer registered WASP users to the OBSTEMP form: http://wasp.ast.cam.ac.uk/obstemp .

DIMM seeing

Seeing is provided by a DIMM monitor located nearby the WHT, and it is measured as the full-width half-maximum (FWHM) brightness profile of a star if located at airmass 1.00.  Note that IFU observations are more tolerant of poorer seeing (diameter of the fibres is 2.6"). An instrument-level limit of seeing <3” is adopted due to degradation of guiding quality in poorer seeing.

Transparency

This component defines the minimum transparency (T) required for the observation. In the absence of cloud and Saharan dust, the V-band transparency (i.e. the fraction of top-of-the-atmosphere light reaching the WHT) is ~ 0.88, and likely scales as (0.88)^airmass (i.e. T ~ 0.83 at airmass 1.5, T~ 0.77 at airmass 2). Extinction due to Saharan dust rarely exceeds a few tenths of a magnitude (i.e. reduces transparency by <~ a few tenths) and varies little with position on the sky. Thin cloud, reducing transparency by a few tenths, can be patchy, so only an all-sky average can be predicted (based on the guide-star signal from previous observations).  A limit on transparency (T > 0.4) is adopted to avoid various performance degradations such as guidance on attenuated guide stars, delivery of science data with significantly reduced signal-to-noise ratio and increased risk of precipitation on the telescope optics.

Elevation angle

Users may set the minimum elevation angle (and thus airmass) that their targets should be observed with. An instrument-wide limit of airmass < 3 will be set due to several effects degrading the quality of data at higher airmass: increasing differential refraction; higher extinction; worse light pollution. Please remember to check for the visibility of your target using http://c.ing.iac.es/staralt/ when placing an elevation limit.

Moon distance

Users may specify the minimum angular distance between the moon and the target. Observations under low moon distance may suffer from sky background light gradients across the field, as well as higher levels of reflected light causing spurious signals within the focal plane. 

An instrument-wide lower limit of 30 degrees ensures sky brightness gradients and scattered light effects are kept to a minimum. This limit applies to any observations set with “0 degrees (no constraint)”.

Sky brightness

The maximum V-band surface brightness of the sky (mag / sq. arcsec) required to observe the target. 

The dark-of-moon sky brightness varies by a few tenths of a mag depending on ecliptic and galactic latitude and phase of the solar cycle. With the moon up, the sky can be up to ~4 mag brighter than dark-of-moon, depending on lunar phase, elevation and angular distance from the target. Science observations are carried out mainly during astronomical night, but those OBs tolerating moonlit skies can also use the latest bit of evening twilight, or the earliest bit of morning twilight – the only relevant criterion is sky surface brightness. No observations will be carried out when the sky brightness exceeds that at full moon.

GAIA specific columns

We strongly urge PIs to use the DR3 reference epoch for WEAVE targets.

Objects that are not detected by Gaia must have their coordinates converted onto the Gaia Reference Frame DR3. It is the responsibility of the PI to verify that their provided coordinates are both consistent with the ICRS.

Parallax and proper motions are particularly important for construction of the WEAVE CNAME, to ensure that successive observations (with varying separation in time) of the same target are correctly attributed to the same CNAME.

Information from Gaia is expected to be provided exactly as it is retrieved from the Gaia archive, so parameter definitions, data formats and units remain the same. Please consult the Gaia webpages to further understand their data model.

IFU_PA_REQUEST

IFU_PA_REQUEST allows the catalogue provider to specify a rotation angle of the LIFU, if required. Note that the default value is zero.  Any dithering requested for the field is applied to the rotated LIFU frame.

...

Instrument configuration

Check first what instrument modes are available in the ING announcement of opportunity

OB length

This PROGTEMP component specifies the overall OB length (inclusive of overheads). Please be aware that not all OB lengths are available. 

Arm exposures

It defines how the time within the OB that you wish to observe the target is divided up, by specifying the number of exposures and exposure time within the stipulated OB length.  The listed options of exposure time splits correspond to science open-shutter times (note that every exposure incur a 3-minute overhead).

IMPORTANT: It is not recommended unlocking the arms. Note that different exposure splits (unlocking the arms) in the red and the blue arms will have two consequences: firstly, no dithering will be possible, and secondly, OB length will increase as the observing system cannot execute different exposure splits simultaneously but one only exposure in both arms at a time. For example, requesting one exposure in red, and 12 in blue would cause a significant mismatch in overheads between the two arms.


Binning in the spectral direction

Only listed values are allowed, all other values are forbidden. As an aside, note that there is no facility to request spatial binning. Such a mode would compromise the spectral extraction performance and crosstalk characterisation within the L1 pipeline.

Duplicate this OB 'x' times

This component is entirely optional – validation checks will not fail if there is no 'x' value in the PROGTEMP. If an applicant wishes to duplicate the observations of this target, then duplication would result in the OB this target lives in being duplicated 'x' times, or in other words, one only OB will be generated, but it will be cloned 'x' times when ingested into the observing system.

Furthermore, if PIs want to chain these OBs together, such that the observation of one of these clones increases the chance that the remaining OBs in this group are observed, then a "+" will be added to the end of PROGTEMP. The "+" instructs the WEAVE scheduler to increase the (internal, programme-specific) weight of all OBs in this group. This provides a mechanism to ensure that once a series of observations are started, completion of the chain becomes a progressively higher priority above other OBs from this programme.


OBSTEMP

Whilst PROGTEMP deals with “how” a target is observed, OBSTEMP deals with “when” a target is observed – namely setting the observational constraints required to optimally extract scientific information from the observation.

These constraints represent “worst-case” observing parameters – targets will be observed under these conditions or better. Note, however, that the worst case represents a scenario when all worst-case observational constraints meet simultaneously. PIs should note also that the probability of observing targets with highly restrictive OBSTEMP codes may be quite low.

We refer registered WASP users to the OBSTEMP form: http://wasp.ast.cam.ac.uk/obstemp (there is also a copy at ING: https://a.ing.iac.es/weave/obstemp.php).

DIMM seeing

Seeing is provided by a DIMM monitor located nearby the WHT, and it is measured as the full-width half-maximum (FWHM) brightness profile of a star if located at airmass 1.00.  Note that IFU observations are more tolerant of poorer seeing (diameter of the fibres is 2.6"). An instrument-level limit of seeing <3” is adopted due to degradation of guiding quality in poorer seeing.

Transparency

This component defines the minimum transparency (T) required for the observation. In the absence of cloud and Saharan dust, the V-band transparency (i.e. the fraction of top-of-the-atmosphere light reaching the WHT) is ~ 0.88, and likely scales as (0.88)^airmass (i.e. T ~ 0.83 at airmass 1.5, T~ 0.77 at airmass 2). Extinction due to Saharan dust rarely exceeds a few tenths of a magnitude (i.e. reduces transparency by <~ a few tenths) and varies little with position on the sky. Thin cloud, reducing transparency by a few tenths, can be patchy, so only an all-sky average can be predicted (based on the guide-star signal from previous observations).  A limit on transparency (T > 0.4) is adopted to avoid various performance degradations such as guidance on attenuated guide stars, delivery of science data with significantly reduced signal-to-noise ratio and increased risk of precipitation on the telescope optics.

Elevation angle

Users may set the minimum elevation angle (and thus airmass) that their targets should be observed with. An instrument-wide limit of airmass < 3 will be set due to several effects degrading the quality of data at higher airmass: increasing differential refraction; higher extinction; worse light pollution. Please remember to check for the visibility of your target using http://c.ing.iac.es/staralt/ when placing an elevation limit.

Moon distance

Users may specify the minimum angular distance between the moon and the target. Observations under low moon distance may suffer from sky background light gradients across the field, as well as higher levels of reflected light causing spurious signals within the focal plane. 

An instrument-wide lower limit of 30 degrees ensures sky brightness gradients and scattered light effects are kept to a minimum. This limit applies to any observations set with “0 degrees (no constraint)”.

Sky brightness

The maximum V-band surface brightness of the sky (mag / sq. arcsec) required to observe the target. 

The dark-of-moon sky brightness varies by a few tenths of a mag depending on ecliptic and galactic latitude and phase of the solar cycle. With the moon up, the sky can be up to ~4 mag brighter than dark-of-moon, depending on lunar phase, elevation and angular distance from the target. Science observations are carried out mainly during astronomical night, but those OBs tolerating moonlit skies can also use the latest bit of evening twilight, or the earliest bit of morning twilight – the only relevant criterion is sky surface brightness. No observations will be carried out when the sky brightness exceeds that at full moon.

GAIA specific columns

We strongly urge PIs to use the DR3 reference epoch for WEAVE targets.

Objects that are not detected by Gaia must have their coordinates converted onto the Gaia Reference Frame DR3. It is the responsibility of the PI to verify that their provided coordinates are both consistent with the ICRS.

Parallax and proper motions are particularly important for construction of the WEAVE CNAME, to ensure that successive observations (with varying separation in time) of the same target are correctly attributed to the same CNAME.

Information from Gaia is expected to be provided exactly as it is retrieved from the Gaia archive, so parameter definitions, data formats and units remain the same. Please consult the Gaia webpages to further understand their data model.

IFU_PA_REQUEST

IFU_PA_REQUEST allows the catalogue provider to specify a rotation angle (position angle) of the LIFU, if this is required.  Any dithering requested for the field is applied to the rotated LIFU frame.  If a specific PA value is not requested, then the following defaults are applied: IFU_PA=0° (for declinations lower than 28.7°) and IFU_PA=180° (for declinations higher than 28.7°). Note that the requested IFU_PA could be changed by the IFU workflow software if a suitable guiding star cannot be found at the requested PA. Below it's a plot which shows how the PA is changed to find a suitable guiding star.

Image Added  

IMPORTANT: During the IFU observation preparation using the IFU workflow software, an analysis is performed on putative LIFU pointings to determine if a rotation is required and provides the optimal value IFU_PA should take.  Rotation is generally used in cases where the default or requested PA results in no viable guide stars falling within the autoguider field of view, or when the rotation during an exposure is likely to exceed the angular limits of the rotator. This means that it's not always possible that the IFU workflow software can provide the IFU_PA_REQUEST value in the catalogue. The table below shows the allowed IFU_PA_REQUEST (=PA in the table) ranges PIs can safely apply for. Maximum value of PA is 360º.



h_min=50.28 (X=1.3)
OBSTEMP: __A__

h_min=45.58 (X=1.4)
OBSTEMP: __B__
h_min=41.81 (X=1.5)
OBSTEMP:  __C__
h_min=38.68 (X=1.6)
OBSTEMP:  __D__
h_min=33.75 (X=1.8)
OBSTEMP:  __E__
h_min=25.00 (X=2.4)
OBSTEMP:  __F__
Dec (°)PA range (°)PA range (°)PA range (°)PA range (°)PA range (°)PA range (°)
-25







225<PA<135-135 → 0 → +135245<PA<115-115 → 0 → +115
-10220<PA<140-140 → 0 → +140235<PA<125-125 → 0 → +125245<PA<115-115 → 0 → +115245<PA<115-115 → 0 → +115250<PA<110-110 → 0 → +110260<PA<100-100 → 0 → +100
0250<PA<110-110 → 0 → +110255<PA<105-105 → 0 → +105255<PA<105-105 → 0 → +105260<PA<100-100 → 0 → +100260<PA<100-100 → 0 → +100270<PA<90-90 → 0 → +90
+15270<PA<90-90 → 0 → +90270<PA<90-90 → 0 → +90270<PA<90-90 → 0 → +90270<PA<90-90 → 0 → +90275<PA<85-85 → 0 → +85275<PA<85-85 → 0 → +85
+28.70295<PA<65-65 → 0 → +65295<PA<65-65 → 0 → +65295<PA<65-65 → 0 → +65295<PA<65-65 → 0 → +65295<PA<65-65 → 0 → +65295<PA<65-65 → 0 → +65
+30130<PA<230-130→ 180 → +130130<PA<230-130 → 180 → +130130<PA<230-130 → 180 → +130130<PA<230-130 → 180 → +130135<PA<225-135 → 180 → +135135<PA<225-135 → 180 → +135
+40115<PA<245-115 → 180 → +115120<PA<240-120 → 180 → +120120<PA<240-125 → 180 → +125120<PA<240-125 → 180 → +125130<PA<230-130 → 180 → +130135<PA<225-135 → 180 → +135
+50105<PA<255-105 → 180 → +105100<PA<260-100 → 180 → +100115<PA<245-115 → 180 → +115120<PA<240-120 → 180 → +120120<PA<240-125 → 180 → +125135<PA<225-135 → 180 → +135
+6080<PA<280-80 → 180 → +8095<PA<265-95 → 180 → +95105<PA<255-105 → 180 → +105110<PA<250-110 → 180 → +110120<PA<240-120 → 180 → +120130<PA<230-130 → 180 → +130
+70

65<PA<295-65 → 180 → +6585<PA<275-85 → 180 → +8595<PA<265-95 → 180 → +95110<PA<250-110 → 180 → +110120<PA<240-125 → 180 → +125
+80





35<PA<325-35 → 180 → +3590<PA<270-90 → 180 → +90140<PA<220-140 → 180 → +140

IFU_DITHER

IFU_DITHER allows the PI to specify the dithering strategy for their observations, but may alternatively request not to dither their observations, with the understanding that this will not provide full spatial coverage of their requested field.
PIs may request the preset -3, 3, 4, 5 and 6-dither patterns. The LIFU preset patterns will be properly rotated according to the position angle of the observation. 

IMPORTANT: Exposure options for which fixed dither patterns are available in IFU modes are 3x, 4x, 5x, 6x.


For custom dither patterns, constraints on the dither step size are imposed by the WASP to ensure that the guide star remains within the guiding camera field of view. From the perspective of IFU users, careful consideration of the dithering options should be made. Below it's an example of custom dithering. Note that pointings are provided for each dither, rather than the dither pointings from an initial positionposition. The three pointings provided in the example below would be executed as part of one only OB.

# A custom 3-dither pattern LIFU pointing

TARGID,TARGNAME,GAIA_RA,GAIA_DEC,PROGTEMP,OBSTEMP,IFU_DITHER
PSZ1_125A,PSZ1_125A,316.369609537,-4.71060356792,41331,IAEEB,-1
PSZ1_125A,PSZ1_125A,316.369058752,-4.70967250147,41331,IAEEB,-1
PSZ1_125A,PSZ1_125A,316.370143237,-4.70966298315,41331,IAEEB,-1

...

ColumnDescriptionFormatLengthValue(s)UnitsExample
TARGPROOptional description of programmeASCII≤40

WS2023B2-010_001
TARGNAMEThe target nameASCII≤30

M33
TARGIDThe identifier of the target assigned for this programmeASCII≤30

M33_NE
PROGTEMPObserving Programme TemplateASCII8 (fixed)

http://wasp.ast.cam.ac.uk/progtemp


41331.3+
OBSTEMPObserving Constraints TemplateASCII5 (fixed)

http://wasp.ast.cam.ac.uk/obstemp


FAACA
GAIA_ID
GAIA Source IdentifierASCII19



1463976195968535680
GAIA_DR
GAIA Data Release versionI1

2, 3


3
GAIA_RA
Gaia RA of targetF11.7

0...360

degrees178.221875
GAIA_DECGaia Dec of targetF11.7

-90...90

degrees44.123919
GAIA_EPOCH

Gaia Epoch of target

F6.1

2015.5 (DR2), 2016.0 (DR3)

Julian year2016.0
GAIA_PMRA Gaia Proper Motion of target in RAF11.3


mas/yr12.1
GAIA_PMDECGaia Proper Motion of target in DecF11.3mas/yr0.01GAIA_PARAL
Gaia Parallax of targetF10.3mas0.002IFU_PA_REQUEST
Position Angle of IFU bundleF11.7

-180...180

degrees106.701IFU_DITHER
IFU dither pattern codeI2

-3, -1, 0, 3, 4, 5, 6

3

Below it's an example of a CSV catalogue file:

TARGID,TARGNAME,GAIA_RA,GAIA_DEC,PROGTEMP,OBSTEMP,IFU_DITHER
IC768_1,IC768,76.7836980,18.1489034,61331.3,DAFEA,3
GHMon,GHMon_NW,32.591451,23.910124,60881,IADEE,4
SN2024gtp,SN2024gtp,102.644083,+68.252231,43331.3,DACEA,6
M101HIIregionC1,M101HIIregion,161.2533346,-11.7653604,51001.7+,AAAEA,0


mas/yr0.01
GAIA_PARAL
Gaia Parallax of targetF10.3


mas0.002
IFU_PA_REQUEST
Position Angle of IFU bundleF11.7

-180...180

degrees106.701
IFU_DITHER
IFU dither pattern codeI2

-3, -1, 0, 3, 4, 5, 6


3


Aladin overlays of the LIFU footprints

...

The edited catalogue must go through the IFU workflow, a set of scripts which will make a version of the FITS catalogue suitable for uploading to WASP (http://wasp.ast.cam.ac.uk/catsubmit/upload) for validation First log on using the provided credentials (the ones emailed from WASP), note that you need to register your IP at http://wasp.ast.cam.ac.uk/ipsubmit/upload first. See below the tab used for uploading the catalogue.

...

At ING, we can provide assistance in guiding you through the different stages of the IFU workflow package, or we can even process your catalogue provided in any of the formats described above, on your behalf. Please contactIn this latter case, simply email your catalogue to the contact below:

weave_open_time_support@ing.iac.es

...

At ING, we can provide assistance in generating the OBs from the CNAMEd catalogue, please contact:

weave_open_time_support@ing.iac.es

OB upload to WASP

The processed OBs can be then uploaded, as a tar file if many, to http://wasp.ast.cam.ac.uk/xmlsubmit/upload (see below). Remember to log on first.

...

In the figure below we show an example of 6 OBs uploaded whose validation failed (the generated report will tell you why). The "Submission Management" button gives access you to all the catalogue and OB uploads made by the user. Submission management allows the user to manage all FITS and OB submissions and select the ones active.

Image Removed

...

Note that if you have requested OB repetitions (for instance, PROGTEMP=41331.5

...

, or 5 OB copies), then only one OB is validated on WASP (not 5 OBs following the example). The OB copies are actually made at the time they are ingested into the observing queue according to the information encoded in PROGTEMP.

IMPORTANT: Don't forget to select the right OBs in the submission maganement! Otherwise, they won't be queued. 

Image Added

Observations and follow up

...